f98b5d00a4
The old defaults (StartLimitIntervalSec=600, StartLimitBurst=5, RestartSec=30) meant any network outage over ~5 minutes would permanently kill the gateway until manual intervention. Changes: - StartLimitIntervalSec=0 (never give up) - Restart=always (not just on-failure) - RestartSec=60 with RestartMaxDelaySec=300, RestartSteps=5 (exponential backoff: 60 → 120 → 180 → 240 → 300s cap) - After=network-online.target + Wants= (both units now wait for actual connectivity, not just network.target) Power outage → internet down → internet back = auto-recovery.