mirror of
https://github.com/NousResearch/hermes-agent.git
synced 2026-05-21 03:39:54 +00:00
c5688e7c8b
When compression fails after max attempts, the agent returns
{completed: False, partial: True} but was missing the 'failed' flag.
The gateway's agent_failed_early guard checked for 'failed' AND
'not final_response', but _run_agent_blocking always converts errors
to final_response — making the guard dead code. This caused the
oversized session to persist, creating an infinite fail loop where
every subsequent message hits the same compression failure.
Changes:
- run_agent.py: add 'failed: True' and 'compression_exhausted: True'
to all 5 compression-exhaustion return paths
- gateway/run.py (_run_agent_blocking): forward 'failed' and
'compression_exhausted' flags through to the caller
- gateway/run.py (_handle_message_with_agent): fix agent_failed_early
to check bool(failed) without the broken 'not final_response' clause;
auto-reset the session when compression is exhausted so the next
message starts fresh
- Update tests to match new guard logic and add
TestCompressionExhaustedFlag test class
Closes #9893